Jump to: navigation, search

Variables Specified in the INWANT Namelist

INWANT is specified in input file (K or boundary inputs) for advanced options. Variables which have no defaults (and thus require inputs??) are printed in bold.


ALPAX Initial value of coefficient alpha (specified by JBETA) of parametrization of P' to be modified to satisfy beta constraint. (Note that this coefficient is unable to change sign during iteration in order to satisfy the constraint.) Default = 104
CCOILS Matrix which defines constraint for F coil currents I1, I2, ..., I18 of the form

CCOILS(1,i) I1 + CCOILS(2,i) I2 + ... + CCOILS(18,i) I18 = XCOILS(i)for i=1,KCCOILS. Constraint applies in fixed boundary solutions only??

CURRC139 Current in 139 degree C coil in Amps. Default = 0.0
CURRC79 Current in 79 degree C coil in Amps. Default = 0.0
FBETAN desired value for normalized toroidal beta
FBETAP Fixed betap value for equilibrium calculation. ICONVR must equal 3. ICURRT must equal 2. Default = 0.0
FITDELZ See namelist EFITIN.
FLI Fixed li value for equilibrium calculation. ICONVR must equal 3. ICURRT must equal 2. Default = 0.0
FQSIW Desired q value at surface PSIWANT, if near boundary FWTCUR (in namelist IN1) must be set to 0.
FWTBDRY See namelist IN1.
FWTXXJ constraint weight for Js, Default = 1.0
FWTXXQ Default = 1.0
FWTXXB Default = 1.0
FWTXLI Default = 1.0
GAMAX initial guess for the li constraint, array element should be as specified through JLI. Default GAMAX(JLI) = -106
JBETA Which coefficient alpha in P' parametrization to vary to get desired betaN = FBETAN value. Assumes polynomial parametrization. Default = 1
JLI Which coefficient gamma in FF' parametrization to vary to get desired li= FLI value. Assumes polynomial parametrization. Default = 2
JWANTM Iteration number when constraints (which ones? all from all namelists?) start. Default = 3
KCCOILS + = number of constraints for F coil currents specified through matrix CCOILS and vector XCOILS. Default = 0
NCCOIL See namelist EFITIN.
NQWANT What is this? Default = 0
NDELZON See namelist EFITIN.
N_WRITE Default = 1
PSIWANT See namelist IN1.
REXPAN See namelist EFITIN.
SCALEDZ See namelist EFITIN.
SIZEROJ See namelist EFITIN.
SIWANTQ want q to be a particular value at some flux surface?
STABDZ See namelist EFITIN.
VZEROJ See namelist IN1.
WRITEPC Default = .false.
XCOILS Constraint vector for F coil currents when KCCOILS>0.
ZNOSE See namelist EFITIN.


Variables Listed in the IN1 Namelist That are Not Used

CLOOPS not used
FQ95 fitting of q95? default = 0.0, not used.
KCLOOPS not used
XLOOPS not used